Description Basic electrode, core wire alloyed, used for the welding of nickel-chromium-iron alloys to themselves as well as for dissimilar welding between various nickel alloys and carbon or stainless steels. There is a large range of applications from cryogenic temperatures up to 1500⁰F. These electrodes can also be used for overlay cladding where similar alloy is needed. |
Description
Weld metal deposit analysis
Mechanical Test of weld Metal
Operating Data
Re – drying: if necessary: 250 – 300 ºC, min. 2 h. |
Welding Positions
- All, except vertical down
Polarity
- DC (+)